Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, Diffuser broke. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. Also be sure the vent holes for the motor are not blocked. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. The pipe connection became disconnected and flooded the pool house overnight after initial opening and start up Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). Hey John Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. Hi i have a Hayward super pump when I turn it on it doesnt suck any water from the pool the filter pressure gauge is at 0 when I turn it off it makes a spinning noice. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. Hi Rose, Its common that winterized pumps may freeze up, caused by a rust layer inside the motor. I have a Hayward pump making more of a rattling sound inconsistent in nature. Automation, Learn About The small filter, usually at the wall? After reinstalling, give it the full charge of DE powder, plus a little extra. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Everything seems to be set up correctly on the filter and motor. We opened our pool today, and when we went out to turn off the Hayward pump, after it ran for 7 hours, the plug was so hot it burned my fingers when unplugging it. Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. If you havent inspected your cell yet, now is aperfect time. Could also be a clog in the pipe. I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Turn on heater and see if you can narrow down the noise. Fingers crossed it is not that! Hi Steve, this can be from reduced flow, like a VS pump running on low speed, and some water vaporizing into steam. Hi the strainer housing must need to be tightened up. Remove the 6 bolts that hold the seal plate to the pump housing Check the shaft, to see that it is spinning freely, then check the wiring to be sure no bare wires are touching bare metal, or each other, or is corroded, and that all wiring is tight and clean. Was working fine until I backwashed and cleaned the basket by the pump. Plate appeared to be good. Hello, my motor runs for 20 seconds then stops. Or buy a new motor. Thinking its the compressor or really dont know at this point. Almost ordered a new pump but it really sounded good. Hi Jennifer, many Matrix pumps have an on/off switch on the rear bottom of the motor cap end. Tried again and again to start, but just keep hearing a click sound and nothing happens. A pump that simply wont start is a frustrating problem. I calibrated the unit to 3100 ppm. If you can determine where the sound is coming from (motor or controller), that will help narrow it down. My Hayward Pump will pull the water through the basket really strong for about 45 seconds then the flow will stop for 20 seconds and the flow will then resume again. Hi you are getting power inside the motor, on the terminal board? Lots of things to check, but its either air entering the system, or an obstruction, both on the suction side of the pump, or before the impeller. Use jumper wire to jump TH terminals. We dont have mechanical time clocksit is all digital. If dead, you can replace just the motor and shaft seal, re-using the pump and impeller. https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. Davy, Ok I switched out the capacitor and it started up and ran for about 5 second and then blew the capacitor. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) Suggestions ? American Freight San Antonio, Check that hoses are clamped tight to fitting. Hi Mark, hard to say if it does not display any error code, the caution symbol on a Hayward Heater is usually accompanied by an error code, LO being the most common, for low water flow. Cavitation refers to a pump being starved for water, and as you describe the water level in the pump basket is low, but also the pump makes a grinding noise, like its gargling rocks. 7. v when it is turned to 230v and re wired for 220-230 v it makes no noise at all. Any ideas why? I would call back the electrician, he may have fumbled this while wiring it, such a problem is rare, and could hardly be blamed on the manufacturer, but if your electrician says that its not his fault, have him put in writing on company letterhead, what the defect of the motor is which can help you in getting warranty assistance. Either a leaky valve in front of the pump, loose fitting threaded into pump, or loose pump lid/o-ring, or sometimes a loose drain plug, with no Teflon tape on it, and a missing plug o-ring these can all allow air to draw into the pump. Is it rigid PVC or flexible pipe? For the green water, drop the pH to 7.2 and add enough shock until the water turns blue-ish, and run the filter 24/7. Put your foot on the motor and apply a little weight, to see if the noise stops. Do I need to clean filter? Ive tried connecting direct from circuit breaker, as well as bypassing with a timer. Hi Chris, the first thing I would check, since the motor is making no noise at all (? please update your current version of Internet Explorer or try using a different browser. }
. Also keep in mind that 1 lb of DE powder is not 16 oz of kitchen dry measure, but actually 32 oz (4 cups) of kitchen measure, because DE is so light and fluffy The normal unit of measure for 1 lb of DE powder is a 1 lb coffee can (or 4 8 oz cups). The problem that I have is when I try to start the vacuum to clean the pool. There may be some stray voltage running around the system, on the bonding wire. I would inspect it for corrosion, wire tightness, water damage or insect damage. Hi Paul, could it be vibration noise? Bob. 1. check that the pump impeller and shaft are spinning freely. I will be replacing it tomorrow along with the electric socket. Why is this happening? Next year, June 21, 2021, is the date that VS (Variable Speed) pumps will be required, over 1-hp in size. Pumps need 120V, +/- 10%, so maybe the voltage is fluctuating, from loose connection from breaker to outlet, or a loose breaker. Checked the connection, which seems fine. Air leaks are from a loose pump lid or dry pump lid o-ring, or from a loose pipe coming into the pump, or from leaky suction-side valves (SK/MD). It could also be a bad capacitor, which is like a battery, to start the motor. I never had this problem before. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. For Pools up to 40,000 gallons. Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? switch in the center. IF thats good, check the pipe coming into the pump, does it drip when the pump is off? I have a Hayward E40, After I vacuum the pool I see that I have D.E on the bottom again after two days or so. This is a salt pool not sure if that matters in the question. There are ants around the AutoChlor, the lights come on but which is the problem, the pump or the switching system? Hello , This is an inactive thread. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. If you lose suction, and the pressure gauge is normal, or lower than normal, that would indicate an air leak in the hose or pipe, or pump, or a clogged pump basket. Whats that part called in case I do break it? Any idea of the problem?? Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. What can I do? The GFI doesnt break which is where the pump is plugged into, it is just the breaker on the eletrical box that pops. Corrosion inside the plug or socket. Lube Gasket (after cleaning, with a rag lube with Teflon or Silicone based pool lube) and 3. Copyright 2022 In The Swim. "keywords": "",
I replaced the pump thinking it was bad. One thing you can attempt is a superglue repair, which I have done successfully on many multiport valves, but not on a pump body. Pump should be OK, I would think. Hi Jeanette, somewhat normal with sand filters I would say first. Backwash several times to remove as much DE powder as possible, and then add 4 cups of DE powder for every 10 sq ft of filter surface area (see filter label if unsure). Flipping the switch makes nothing happen. *new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. Didnt I switched it off properly? If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. Pump is 4yrs old. After troubleshooting using your TS guide, I found on page 36 where it says to check the top rectifier I have 24VAC from the board (where the orange wire plugs into) to the ground. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. Hayward has a 4 year warranty on these drives. Inspect for any damage to wires or wire casing. It is only in its 3rd season. Anyone have this issue or have any recommendations? Check the capacitor, for bulging, cracking, or melting. Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. I next realized the shaft (impellers) was frozen, and was able to free it up so it now spins smoothly. "width": "611",
If the water is running down between the pump and motor, determine if its dripping out of the plumbing fitting on top or the shaft seal on the bottom. If not, then it will usually be a bad capacitor, or start capacitor, located at 9 oclock, in the rear, a black cylinder. Ive checked out your blog and you had very good info for audience. All works good now. Give the cell an acid soak and it should clear the blockage. I even removed the outflow from the filter and ran that directly in case the filter was clogged. Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. it does not turn on even though i get 240 volts.My blower is on a different circuit and works properly with 240 volts. The third thing to check would be an obstruction on the pressure side of the pump, clogged impeller, clogged filter, closed return side valves or plugs in the wall. Troubleshooting Guides | Support Center | Hayward Residential and The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). It could also be something wrong with the motor, something internal with the windings, or shaft, or bearings, causing excess heat. any ideas? Any advice?? But not likely, since its been there for years. No change. Now there is no water running from the pool to the motor basket. I let the pump cool down, then reset the thermal switch and it runs for another hour and shuts off again.The wiring is the same and it doesnt trip the breaker switch. Even if it looks good, it could be bad. To view these documents, you will need to download the free Acrobat Reader, which },
Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. Checked to see that there was no short in the wire with an ohms meter . "image": {
Is it likely to be the pump or the AutoChlor switches and timer (which I replaced last year)? Please advise ). Is this normal? Wouldnt turn back on for a while even after manually flipping the switch. Hayward Blue Essence Troubleshooting, I think I have some air leakage on my supply side of my Hayward Super Pump. the , . What are the amp and volt readings for the new cell? Pressing on/off buttom followed only by click sound of switch. Sometimes you can pull out the clog with needle nose pliers. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. Thanks for the schema!! No matter where we move dial we have water coming out the back wash pipe. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Im having an air leak problem with my pool. Please help! "name": "Mark Garcia",
If you need a new one in a few days, I would not consider getting one from Hayward, that could take a month. Yesterday the breaker tripped. I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. Using a Slime Bag, attached to the pool return, to act as a secondary filter, would be a solution. Water Features, View All A pool guy who has since stopped operating put it in. We are a registered 501(c)3 non-profit that is funded by user donations. replace the entire pump with exact replacement. with UV, Ozone and Hydroxyl Radicals. Just replaced our pool pump, Hayward 1 hp self priming, super pump. I have it on a 15 amp breaker with a few other items, the motor after running is very hot to the touch. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. Shut off power at the breaker to all pool equipment http://bit.ly/InyoPoolsListen to the Poolside Chat podcast!iTunes:http://bit.ly/PoolsideChatSoundCloud:https://soundcloud.com/inyopools-comLIKE us on FACEBOOK! Round about 1990 the original AG pump and filter were replaced with used Hayward IG equipment. 4. inspect capacitor, usually mounted at 9 oclock, for signs of leaking, bulging, cracking Hi Davy, How are you supposed to move the shaft several revolutions with a 7/16 wrench with all the pegs in the way and the shaft only having two flat sides to get the wrench to lock on to it??? All Please help. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. Salt Chlorinator Problems - Repair or Replace? - InTheSwim Pool Blog What do numbers on T-Cell-15 digital display mean? | Aqua Rite It is brand new. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Nothing seems to give it juice. After trying every chemical under the sun and replacing the sand, I pulled the trigger and started from scratch. 2 year warranty. The blower will continue to run. Good that you have the waterfall pump, that will help tremendously. Ive read online it is most liked a valve that is faulty in some way. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. Has more of an impeller type sound. Its a 16-14 250 amp connection. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. The pump stopped priming and allowed water to just flow through but not pressurize the closed filter basket part that is right before the pumpso it looks like a waterfall in the basket flowing from the pipe coming from the pool to the lower end going into the filter. Any ideas on how to fix this issue?? I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. After the click, immediately push the diagnostic button 5 times to begin the recalibration stage. I have my pump to run each evening from 10:30pm to 9:30am. But the clicking, that sounds like a centrifugal switch, on the rear of the shaft, which could be a voltage issue? Check electrical connections and wiring for loose or broken. Slo puedes comparar 4 propiedades, cualquier nueva propiedad aadida reemplazar a la primera de la comparacin. Pump lid not on tight enough If I shut the pump off for a little while and put it back on it repeats the same thing over and over, strong at first for about 5 minutes then weak. If thats not it pull the motor out of the pump, and test the motor briefly to see if the sound continues, if so I would expect bad bearings, or perhaps a loose shim washer, inside the motor, under the front or rear end bell. Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. Backwash works but not filter.. we took it apart and replaced the housing gasket, diffuser gasket and seal shaft. Thought he motor was defective. Troubleshooting a Hayward Aqua Rite can be quick and simple. Water level is good, pipe connections are sealed and I checked I rings which seem fineI cant seem to figure out what is wrong.